The human-facing index of every manufacturer and SKU the wiki has run into for hydrogen sensing: 112 vendors, 209 products (167 with specs verified against a datasheet, 172 with a datasheet link). Each product links to the modality page that explains how it works.

When you run into a new sensor, instrument, or component:

  1. Add or extend a YAML under src/data/vendors/<vendor-slug>.yaml, following docs/templates/vendor-schema.md. One file per vendor — if the vendor exists, append the new SKU to its products: list.
  2. Re-run python3 ops/generate-vendors.py to rebuild this page, then npm run build.
  3. Optionally add a row to the relevant modality page’s Vendors & products table for in-context discovery.

Only record vendors, products, and specs that appear in a research dossier or a real datasheet. Carry over any (unverified) flags; do not invent SKUs, prices, or specs. Price classes: $ <$100, $$ $100–1k, $$$ $1k–10k, $$$$ >$10k, unknown. A ✓ marks specs taken from a manufacturer datasheet.

VendorProduct / SKUKey specsPriceDatasheetModality
AlphasenseH2-AF — A-series portable H₂ sensor0–2000 ppm warranted; 10–40 nA/ppm @400 ppm/23°C; T90 <35 s; zero ±15 ppm; <0.7 ppm RMS noise; zero drift <20 ppm/yr; >24 mo life; −30…+50 °C; 80–120 kPa; 15–90% RH; CO <2% @400 ppm ✓$$datasheetpage
AlphasenseH2-BF — B-series H₂ sensor0–5000 ppm warranted (20,000 ppm overgas); 10–25 nA/ppm @400 ppm; T90 <55 s; zero <±15 ppm; <0.8 ppm RMS noise; zero drift <10 ppm/yr; >24 mo life; −30…+50 °C; 15–90% RH; CO <2% @400 ppm ✓$$datasheetpage
DD-ScientificDceL H2-1000 — DceL miniature electrochemical H₂ sensor, low range0–1000 ppm; 20±10 nA/ppm; T90 <40 s (typ. <25 s); 0 V bias; 3-pin low-profile package, interchangeable with 4-series; 12-mo warranty; low CO cross-sensitivity ✓$datasheetpage
DD-ScientificGS+4H2-CO 1000 — GS+4H2-CO electrochemical H₂ sensor, 4-series, low CO cross-sensitivity0–1000 ppm; 20±10 nA/ppm; T90 <40 s (typ. <25 s); 0 V bias; 12-mo warranty; low CO cross-sensitivity; 4-series pin-compatible ✓$datasheetpage
DD-ScientificGS+4H2-CO 5% — GS+4H2-CO electrochemical H₂ sensor, 4-series, extended range 0–5 vol%0–50,000 ppm (0–5 vol%); 0.5±0.25 nA/ppm; T90 <40 s (typ. <20 s); 0 V bias; 4-series 3-pin; 12-mo warranty; low CO cross-sensitivity ✓$datasheetpage
DD-ScientificGS+4H2-CO 5000 — GS+4H2-CO electrochemical H₂ sensor, 4-series, high range, low CO cross-sensitivity0–5000 ppm; 10±5 nA/ppm; T90 <40 s (typ. <25 s); 0 V bias; 4-series 3-pin; 12-mo warranty; low CO cross-sensitivity ✓$datasheetpage
DD-ScientificGS+7H2 — GS+7H2 electrochemical H₂ sensor, 7-series0–1000 ppm; 20±10 nA/ppm; T90 <90 s; 0 V bias; 12-mo warranty; low CO cross-sensitivity marketed; fixed-installation 7-series package ✓$$datasheetpage
DrägerCatEx 125 PR (PN 6812950) — DrägerSensor CatEx catalytic sensing head0–100 %LEL / 0–100 vol% CH₄; res 1 %LEL / 1 vol%; methane→nonane certified; new PR pellistor composition vs H₂S & silicone poisoning; lead-free; for X-am 2500/5000/8000 ✓$$$datasheetpage
DrägerX-am 8000 — X-am 8000 portable multi-gas (XXS H2 HC)1–7 gas detector; internal pump option (hose ≤45 m); configurable EC (XXS), IR, PID, and CatEx 125 PR sensor slots; inductive charging; IP-rated; H₂ via XXS H2 HC (0–4 vol%) ✓$$$datasheetpage
DrägerXXS H2 (PN 6812370) — XXS H₂ electrochemical sensor, low concentration (X-am 5000/5600/8000)0–2000 ppm; 6-month calibration interval; 1-yr warranty; miniature electrochemical XXS package; for Dräger Pac, X-am 5000/5600/8000 ✓$$$datasheetpage
DrägerXXS H2 HC (PN 6812025) — XXS H₂ electrochemical sensor, high concentration0–4 vol% (0–40,000 ppm); 5 ppm resolution; 1-yr warranty; miniature XXS package; used in X-am 8000 for 0–100% LEL H₂ readings ✓$$$datasheetpage
EC Sense01-ES4-H2-5000-01 — ES4-H2-5000 solid-polymer-electrolyte H₂ sensor element0–5000 ppm (20,000 ppm overload); 3±2 nA/ppm; T50 <10 s, T90 <30 s; 1 ppm resolution (16-bit ADC); 0 mV bias; -40…+55°C, 15–95% RH; >5 yr life; <5%/yr drift ✓$$datasheetpage
EC Sense04-TB200B-ES4-H2-5000-01 — TB200B-ES4 smart H₂ sensor module (UART/I²C)0–5000 ppm, 1 ppm resolution; T50 <10 s, T90 <30 s; onboard T/RH sensing; UART (TTL 3.3V) or I²C output; 3.3–5.5 V, <5 mA (40 mW); sleep mode; -40…+55°C, 15–95% RH; >5 yr life; 12-mo warranty ✓$$datasheetpage
Honeywell4HYT — 4-Series electrochemical H₂ sensor (City Technology)0–1000 ppm H₂ (2000 ppm overload); 15±10 nA/ppm; resolution 2 ppm; T90 <90 s; drift <2%/mo; −20 to +50 °C; 2-yr life in air ✓$$datasheetpage
HoneywellCAT25 / CAT16 — CiTipeL CAT catalytic bead seriesT90 < 10 s (CH₄); 230 mW max; life > 2 yr; span drift < ±2 %LEL CH₄/yr; some HMDS/H₂S poison resistance; H₂ relative sensitivity 107 (CH₄=100) ✓$$datasheetpage
HoneywellHydrogen Leak Detector (HLD, 2025) — Portable TCD hydrogen leak detectorTCD; 0–4% H₂ (0–40,000 ppm); 50 ppm resolution; ±10% accuracy (−40 to 65 °C); T90 <2 s; startup <1 s; CAN J1939, 250 kBaud; −40 to 85 °C; IP67; 16 mA @12 V ✓$$datasheetpage
MembraporH2/C-20000 — H2 sensor, compact housing, 50% LEL0–20,000 ppm (40,000 ppm overload, 50% LEL H₂); 6±4 nA/ppm; T90 <45 s; <8.4 ppm resolution; CO cross-sens. ~60–80%; −40…+50 °C ✓$$datasheetpage
MembraporH2/C-40000 — H2 sensor, compact housing, 100% LEL0–40,000 ppm (80,000 ppm overload, 100% LEL H₂); 4±3 nA/ppm; T90 <45 s; <12.5 ppm resolution; CO cross-sens. <100%; −40…+50 °C; safety/process control ✓$$datasheetpage
MembraporH2/C-5000 — H2 sensor, compact housing, mid-range0–5000 ppm (10,000 ppm overload); 9±2 nA/ppm; T90 <45 s; <5.3 ppm resolution; CO cross-sens. ~60–80%; −40…+50 °C; 15–90% RH ✓$$datasheetpage
MembraporH2/CA-1000 — H2 sensor, compact housing, CO-filtered0–1000 ppm (2000 ppm overload); 28±11 nA/ppm; T90 <40 s; <1.8 ppm resolution; inboard CO filter (600 ppm CO → <18 ppm reading); zero drift <15%/yr; −40…+50 °C; 15–90% RH; 3–5 yr life ✓$$datasheetpage
MembraporH2/CT-40000 — H2 sensor, compact housing, high-humidity/biogas0–40,000 ppm (50,000 ppm overload, 100% LEL H₂); 4±3 nA/ppm; T90 <45 s; rated to 50–95% RH (biogas/high-humidity duty); −40…+50 °C ✓$$datasheetpage
MembraporH2/M-1000 — H2 sensor, miniature housing0–1000 ppm (2000 ppm overload); 25±10 nA/ppm; T90 <35 s; <2.0 ppm resolution; no CO filter (CO cross-sens. ~60–80%); zero shift 18 ppm; −40…+50 °C; 5.5 g; portable-device form factor ✓$$datasheetpage
MembraporH2/M-40000 — H2 sensor, miniature housing, 100% LEL0–40,000 ppm (100% LEL H₂); 5±3 nA/ppm; T90 <50 s; <10.0 ppm resolution; zero shift 100 ppm; −40…+50 °C; 5.5 g; portable-device form factor ✓$$datasheetpage
MembraporH2/S-10000-S — H2 sensor, standard housing, 3-electrode, mid-high range0–10,000 ppm (20,000 ppm overload); 6±4 nA/ppm; T90 <45 s; <8.4 ppm resolution; 3-electrode; CO cross-sens. ~60–80%; zero drift <15%/yr; −40…+50 °C; 15–90% RH; 3–5 yr life ✓$$datasheetpage
SemeaTech4H2-1000A — 4-Series electrochemical H₂ sensor, interference-resistant (PN 054-S000-000)0–1000 ppm (2000 ppm overload); 0.02±0.01 µA/ppm; T90 ≤70 s; 0.2 ppm resolution; CO cross-sensitivity eliminated (50 ppm CO → 0 ppm equiv.); -20…50°C, 15–90% RH; 2 yr life; pin-to-pin 4-series replacement ✓$datasheetpage
SemeaTech4H2-40000 — 4-Series electrochemical H₂ sensor, high range (PN 054-0100-000)0–40,000 ppm; 0.010±0.003 µA/ppm; T90 ≤70 s; 5 ppm resolution; 500 ppm CO → 120 ppm H2-equiv. (not interference-resistant); -20…50°C, 20–90% RH; 2 yr life; pin-to-pin 4-series replacement ✓$datasheetpage
SemeaTech7H2-10000 — 7-Series electrochemical H₂ sensor (PN 054-0300-000)0–10,000 ppm (20,000 ppm overload); 0.006±0.003 µA/ppm; T90 ≤110 s; 10 ppm resolution; 50 ppm CO → 200 ppm H2-equiv.; -20…50°C, 15–90% RH; 2 yr life; pin-to-pin 7-series replacement ✓$datasheetpage
SGX SensortechEC4-1000-H2 — Hydrogen electrochemical sensor0–1000 ppm (2000 ppm overload); 10–30 nA/ppm H₂; zero <±20 ppm; resolution 10 ppm; T90 <70 s; drift <2%/mo; −20 to +50 °C; 2-yr warranty; 0 V applied potential ✓$datasheetpage
SGX SensortechMP-7217 (VQ548MP) — MEMS PellistorT90 < 12 s; 110–140 mW cont., <5–10 mW pulsed; −40/+60 °C op (+75 °C cert.); Ø14 mm, 1 g ✓$datasheetpage
SGX SensortechMiCS-2714 — MiCS-27xx MEMS MOXH₂/NO₂; 50 ppb–5 ppm; −30 to 85 °C ✓$datasheetpage
SGX SensortechMiCS-5524 — MiCS-55xx MEMS MOXH₂ secondary channel (CO/methane-primary); indoor CO/gas-leak combo part ✓$datasheetpage
SGX SensortechMiCS-5914 — MiCS-59xx MEMS MOXH₂ 1–1000 ppm; R₀(air) 10–1500 kΩ; sensitivity factor 1.5–15; discontinued generation; ≈$6.24–6.74 ✓$datasheetpage
SGX SensortechSGX-BLD1 — Hydrogen & Battery Leakage Detection sensor (automotive TC module)Thermal-conductivity principle (not FET); 0–10% H₂; ±0.4 vol% (≤4%H₂)/±10% (≥4%H₂); T90 <1 s; <25 mA @ 9–18 V; CAN 500 kbps; IP6K7; −40 to +85 °C; ≥10-yr/13,000 h life ✓$$datasheetpage
SGX SensortechTC-1326-A / TC-1326-AS — MEMS thermal-conductivity sensor elements0–100 vol% H₂/methane; 5 mV/%H₂ min. sensitivity; heat-up <100 ms, cycled avg <15 mW; dual 5×5×2 mm package; op/storage −40 to +125 °C; no catalytic poisoning, O₂-independent ✓$datasheetpage
SGX SensortechVQ21T / VQ21TB / VQ21TSB — VQ21 Series high-power poison-resistant catalytic pellistorFlammable gases incl. H₂; 0.1–5% CH₄ (0–100% LEL); min sensitivity 15 mV/%; 2.0±0.1 V bridge, 300 mA typ., 750 mW max; T50 2 s; linear to 3% CH₄; −40 to +70 °C; >5-yr life; highly silicone/poison-resistant (orders of magnitude vs VQ1); TB/TSB add poison filters/thread mounts ✓$datasheetpage
SGX SensortechVQ548ZD / VQ549ZD / VQ547TS / VQ546M — VQ500 series catalytic bead / TCDT90 < 20 s; 135–230 mW; −40 to +55 °C; ATEX/IECEx/CSA/UL; VQ546M/MR TCD %v/v; bare element ≈ US$30 (VQ548ZD-S) ✓$datasheetpage
Winsen ElectronicsMC105 — MC105 catalytic bead sensor0–100% LEL; 1% CH4 → 20–50 mV, 1% C3H8 → 30–70 mV; T90 ≤10 s, recovery ≤30 s; 2.5±0.1 V, 150±10 mA; 5-yr life; -40…+70°C <95% RH; H2S/organosilicone resistant ✓$datasheetpage
Winsen ElectronicsME3-H2 — ME3-series electrochemical H₂ sensor0–1000 ppm (2000 ppm max); 10.8±5.2 nA/ppm; T90 ≤90 s; 2 ppm resolution; zero drift ≤20 ppm (-20…40°C); 2 yr life; -20…50°C, 15–90% RH; 10Ω load ✓$datasheetpage
Winsen ElectronicsME4-H2 — ME4-series electrochemical H₂ sensor0–1000 ppm (2000 ppm max); (0.03±0.01) µA/ppm; T90 ≤30 s; 1 ppm resolution; zero drift ≤10 ppm (-20…40°C); 2 yr life; -20…50°C, 15–90% RH ✓$datasheetpage
Winsen ElectronicsMQ-8 — MQ-8 SnO₂ Taguchi-type H₂ sensor100–1000 ppm H₂; SnO₂ bead, sensitivity Rs(air)/Rs(1000ppm H2)≥5; heater 5.0±0.1V, ≤950 mW; loop ≤24V DC; 10-yr claimed lifespan; preheat >48 h ✓$datasheetpage
Winsen ElectronicsZE03-H2 — ZE03 electrochemical H₂ module0–1000 ppm; onboard µC, UART + analog output; DC 3.7–9 V, <5 mA; >1 yr working life; 0–50°C, 20–90% RH; ø23.5×24.5 mm ✓$datasheetpage
Winsen ElectronicsZE07-H2 — ZE07 electrochemical H₂ module0–30,000 ppm; 50 ppm resolution; DAC (0.4–2 V) + UART (3V-TTL) output; 5–12 V, warm-up ≤3 min; response/resume ≤60 s; 3–5 yr life; -10…55°C, 15–90% RH ✓$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
BoschBME688 — BME6xy MEMS MOx gas-scan + T/RH/PBroadband ppb VOC/VSC/CO/H₂ but not independently H₂-ppm calibrated (needs BSEC/AI-Studio model); 3.9 mA scan / <0.1 mA ULP; $8.99 bare (DigiKey) ✓$datasheetpage
BoschFuel-cell H2 leak sensor + virtual H2 sensor — FCEV H₂ leak sensing (MEMS + software)Thermal-conductivity principle (Bosch Mobility): H₂ leakage sensor 0–4 vol% ±1.0 vol%; exhaust H₂ sensor 0–10 vol% ±1.0 vol%, 0–100% RH, 0.5–1.3 bar, ASIL-B; plus model-based virtual H₂ sensor (<5% estimation error, up to 100% H₂); CAN interface ✓$datasheetpage
Figaro EngineeringTGS2600 — Air-contaminant MOS sensor~1–30 ppm H₂ (broad multi-gas, not H₂-selective); 5.0V heater, 42±4 mA, ~210 mW; Rh≈83 Ω ✓$datasheetpage
Figaro EngineeringTGS2616-C00 / -C01 — MOS H₂ sensor30–3000 ppm; 280 mW heater; Rs 0.30–3.0 kΩ at 100 ppm H₂; C01 reduces acetylene interference (DGA use); −10 to +50 °C ✓$datasheetpage
Figaro EngineeringTGS6812-D00 — Catalytic H₂/CH₄/LPG bead0–100% LEL H₂/methane/iso-butane; 3.0 V, 175 mA, 525 mW heater; ΔVout 8–16 mV @4000 ppm H₂; −10 to +70 °C; adsorbent cap cuts organic-vapour cross-sensitivity ✓$datasheetpage
Figaro EngineeringTGS8100 — Low-power air-contaminant MOS sensor~1–30 ppm (H₂/ethanol class); 1.8V heater, 8 mA, 15 mW pulsed (~92% power cut vs continuous); SMD; battery-powered equipment ✓$datasheetpage
Figaro EngineeringTGS821 — 'Special' H₂ SnO₂ bead sensor50–4000 ppm (rated floor 50 ppm); Rs 1–10 kΩ @100 ppm; 660 mW heater; slope 0.60–1.20 dec/dec; ~2× T/RH baseline swing; CH₄/EtOH/CO cross-response ($10–20 class) ✓$datasheetpage
Nissha FISFH2-HY04/05/06/11 — Catalytic-combustion H₂ line0–4 vol%; startup ≤1 s, T90 ≤3 s; HY04 12V/PWM (cars/buses/trucks), HY05 12V/CAN 500kbps, HY06 24V/CAN 250-500kbps, HY11 5V/analog; siloxane-resistant; distinct from SB/SP MOX line ✓$datasheetpage
Nissha FISSB-19-00 — SB semiconductor-bead MOXRs 0.2–2 kΩ at 100 ppm H₂; sensitivity slope α 0.6–1.2 (100→1000 ppm); 120 mW heater (0.9V/130mA); O₂-dependency (min >18% O₂, std 21%); −10 to 50 °C, <95% RH; 0.6 g ✓$datasheetpage
Nissha FISSP-19-01 — SP planar MOXOptimized for low-concentration H₂; Rs 0.5–5 kΩ at 100 ppm; slope α 0.60–1.2; 315 mW heater (5.0V/80mA); O₂-dependency (min >18%); −10 to 50 °C, <95% RH; 1.75 g ✓$datasheetpage
Renesas ElectronicsZMOD4410 — ZMOD44xx MEMS MOx + ASICTVOC/IAQ-focused (no standalone H₂-ppm spec); broadband-reactive MOx, 1.7–3.6 V, 12-LGA; datasheet notes high H₂ sensitivity (resistance-based); 10-yr JEDEC-qualified life; mW-class duty-cycled ($5–10 class) ✓$datasheetpage
Renesas ElectronicsZMOD4510 — ZMOD45xx MEMS MOx + ASICO₃/NO₂ oxidizing-gas channel, MOx chemiresistor, 12-LGA; pairs with ZMOD4410 for cross-compensation; 10-yr JEDEC-qualified life ✓$datasheetpage
SensirionSGP4x — SGP4x MEMS MOx VOC/NOx indexVOC/NOx index (not H₂-targeted); SGP40 VOC-only, SGP41 VOC+NOx dual-pixel; I²C, DFN 2.44×2.44×0.85mm; cited for vendor's plain-language MOX-limitation explainer ✓$datasheetpage
SensirionSTC31 / STC31-C — CMOS thermal-conductivity gas sensor0–100 vol% (binary CO₂/N₂/air marketed; TC principle reused for H₂ by analogy); typ. ±0.5 vol% (low-cross-sensitivity mode), ±0.2 vol% best case, up to ±2.0 vol% wide-range; fully functional −40 to 105 °C, 200–2000 mbar; I²C; $24–65 (Digikey) ✓$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
Blackline SafetyLEL-MPS (G7 cartridge) — G7 combustible-gas cartridge (NevadaNano MPS-based)0–100% LEL; 0.1% LEL resolution; licensed Nevada Nano MPS (Molecular Property Spectrometer) sensing element, not classic catalytic bead; alt. LEL-IR (MIPEX NDIR) option also 0–100% LEL/1% LEL res; −20 to 55 °C op., IP67 ✓$$$datasheetpage
MSA SafetyFL500-H2 — FL500-H2 UV/IR hydrogen flame detectorUV 185–260 nm + IR ~2.95 µm; 60 ft (~18 m) range; 2.1 s response to H₂; −55…+85 °C (CSA/ATEX/IECEx), −50…+85 °C (FM); IP66/IP67; FM/CSA/ATEX/UKCA/IECEx ✓$$$datasheetpage
MSA SafetyObserver-i — Observer-i (Gassonic) ultrasonic gas-leak detectorFixed-point (non-imaging) ultrasonic/acoustic leak detector; ANN false-alarm rejection down to 12 kHz; range up to 28 m; T90 <1 s; −40 to +60 °C; IP66/Type 4X; 316 SS housing; 2-yr warranty ✓$$$datasheetpage
MSA SafetySAW MiniCAD mk II — SAW-array chemical-agent detector (Microsensor Systems)Handheld battery SAW-array CWA detector; GB alarm threshold 0.5 mg/m³, 60 s analysis, 2 min warm-up; 0.5 kg; 5-yr shelf life; adjacent precedent, not an H₂ product ✓$$$datasheetpage
MSA SafetyXCell catalytic bead — XCell cat-bead element (Ultima X / S4000CH)Integrated fixed-point cat-bead detector platform with embedded ASIC; life >4 yr typical (2x industry avg per MSA); standard 3-yr warranty; TruCal extends cal interval on select gases ✓$$$datasheetpage
New Cosmos ElectricFCS-H20 (CSD-02/CSD-04) — Catalytic-combustion H₂ sensor for FCEVs0–4 vol% H₂; GTR-13 (FCEV) compliant, used in Toyota Mirai; >15-yr maintenance-free life; low power/size/weight; siloxane-poisoning resistant; automotive variants sold as CSD-02 (PWM out) / CSD-04 (CAN out) ✓$datasheetpage
New Cosmos ElectricKD-12 — Diffusion-type H₂ gas detector head (hydrogen refuelling stations)Fixed diffusion-type detector head with display; developed via New Cosmos hydrogen-diffusion/CFD studies for H₂ refuelling-station leak monitoring; explosion-proof housing$$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
ABBAZ100 — AZ100 zirconia oxygen analyzerIn-situ zirconia O₂ analyzer (not H₂); OEM boiler/burner-controls market; low-temperature type to 600 °C process temp, 400 °C max duct surface temp ✓$$$$datasheetpage
ABBEL3000 Series (Caldos27 TCD) — EasyLine EL3000 with Caldos27 thermal-conductivity sensorSilicon-sensor TCD module; per search-indexed EL3000 datasheet: 0–11 vol% H₂ in air/Ar/CH₄/CO/CO₂/N₂, 0–10 vol% H₂ in NH₃; fast T90 via small cell volume — PDF text not independently re-extracted this session (unverified)$$$datasheetpage
ABBKatharometer Series 6517 — 6517 katharometerThermal-conductivity detector for continuous industrial use; CENELEC EExia IIC (Zone 0) T4, −20/+55 °C ambient; H₂ explicitly in Group IIC coverage; shunt-diode safety barriers ✓$$$$datasheetpage
ABBLGR-ICOS GLA132-GGA / UGGA — LGR OA-ICOS greenhouse-gas analyzerOA-ICOS; CH₄ 0.6–2 ppb; CO₂ 100–300 ppb; extended range to 10% CH₄; 15 kg, 60–66 W ✓$$$$datasheetpage
Baker Hughes / PanametricsXMTCpro — XMTCpro online TC transmitterBinary H₂ in N₂/air/O₂/CO₂, He, CO₂, SO₂, Ar; ranges 0–1% to 0–100% (12 span options); accuracy ±2% of span; T90 20 s; SIL 2 by design (IEC61508 optional); Modbus RS232/RS485, 2×4-20mA; 24 VDC; IP66, ATEX/IECEx ✓$$$$datasheetpage
E/One (Environment One)Generator Gas Analyzer (GGA) — GGA triple-range online TCD70–100% H₂ in air (±0.5% FS); 0–100% H₂/air in CO₂ (±1.0% FS); linearity ±1% FS; drift <0.2%/mo; 500 cc/min nominal; resolution ±0.1%; 4–20 mA self-powered; flameproof/explosion-proof/IS variants ✓$$$$datasheetpage
Eaton / MTL (Crouse-Hinds)K522 / K1550 — K522 katharometer / K1550 gas analyserClassical hot-wire katharometer; ranges 0–5%/0–20%/0–100%/80–100%/95–100% H₂ (gas-dependent); accuracy ±2% FSD; T90 20 s; stability <1% FSD/mo; 4–20 mA + 2 alarm relays; K1550FX ATEX/EEx d IIB+H₂ hazardous-area version ✓$$$$datasheetpage
InfineonXENSIV TCI (TCI-B) — XENSIV TCI MEMS thermal-conductivity sensor0–16 vol% H₂ (LDL 0.1%); ±0.12 vol% accuracy; <100 ms response; −40 to 105 °C; 15-yr lifetime claimed; 112 µA @1 meas./s, 3.3 V, I²C up to 1 Mbit/s; immune to poisoning ✓$datasheetpage
NevadaNanoMPS Flammable Gas Sensor — MPS (Molecular Property Spectrometer)0–100% LEL per-gas (H₂ ±5% LEL @50% LEL), 0.1% LEL res, T90 <20 s, −40 to 75 °C, 0–99% RH non-cond., 8.9 mA avg (5–21 mA range) @3.3–5.0 V, ~29 mW; 12 gases incl. H₂; >1-yr cal interval, >5-yr life ✓$datasheetpage
NevadaNanoMPS H2 Gas Sensor (3.0–6.0 ULP) — MPS Hydrogen sensor variants0–100% LEL H₂; 0.1% LEL res; T90 <20 s; −40 to 75 °C; power by gen: 3.0/4.0 29 mW, 5.0 27.3 mW, 6.0 ULP 1.35 mW; 15-yr sensor life; no field calibration, O₂-independent, TrueLEL-certified alternative to catalytic bead ✓$datasheetpage
Posifa TechnologiesPGS1000 / PGS1004 — PGS1000 MEMS TC H₂ sensor0–4 vol% H₂ (PGS1004); ±6% reading accuracy; T90 1.4 s; 8 mA avg; −40 to 85 °C; I²C 0–40,000 count output; ~$35–45 (small qty); automotive/fuel-cell H₂ leak/level ✓$datasheetpage
Posifa TechnologiesPGS4100 — PGS4100 MEMS TC H₂ sensor0–4 vol%; 10 ppm (analog)/2 ppm (digital) res; ±1200 ppm accuracy 0–20,000 ppm, ±6% above; T90 1 s; −40 to 85/90 °C; 1200 ppm/5 yr stability; 190 mW peak/50 mW avg ✓$datasheetpage
Posifa TechnologiesPGS5100 — PGS5100 MEMS TC H₂ sensor (EV battery / leak safety)0–25 vol% H₂; 2 ppm digital resolution; ±1200 ppm accuracy (0–100% RH, 70–120 kPa), ±6% reading >20,000 ppm @25 °C; T90 100 ms, warm-up 200 ms; 190 mW peak/50 mW avg @5 V; −40 to 85 °C, 0–100% RH condensation-resistant; RH+barometric compensated; RS-485 Modbus RTU (CAN future); IP6K9, automotive connector; >15-yr life; 2nd-gen TC die, SMD ✓$datasheetpage
Xensor IntegrationXEN-TCG3880 / XEN-5310 / XEN-5320 — MEMS thermal-conductivity gauge + readoutTC 9 ms (air), 36 ms (vacuum); 1–3% FS inaccuracy; −40 to +85 °C (module); ~1200 ppm/yr long-term stability (10 ppm short-term); 5–8 V ~20 mA; die ~$10–20 ✓$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
H2scanFleet Advisor — Fleet Advisor transformer-fleet DGA platformContinuous dissolved-gas-analysis monitoring for transformer fleets (not a standalone gas-phase H₂ sensor); now marketed alongside H2cloud/Sentinel IoT platform$$$—page
H2scanGRIDSCAN 5000 / 5000 HP — GRIDSCAN transformer DGA monitor25–5000 ppm (oil & gas phase); accuracy ±25 ppm/±20% (5000) or ±15 ppm/±10% (5000-HP); response <60 min; RS-485 Modbus/DNP3; IP68 (25 ft/14 days); 10+ yr sensor life ✓$$$datasheetpage
H2scanHY-ALERTA 1600 / 5020 / 5021 / 5320 — HY-ALERTA area safety monitors0.4–5% H₂ (10–125% LEL); accuracy ±(0.03×indication+0.2)%H₂; T90 <60 s; −20 to 55 °C; 10-yr sensor warranty, no field calibration; RS-485 Modbus, 4-20mA, optocouplers ✓$$$datasheetpage
H2scanHY-ALERTA 600B / 2620 — HY-ALERTA general-purpose & explosion-proof area monitors0.4–5% H₂ (10–125% LEL); T90 <60 s; 2620 explosion-proof (Ex db IIB+H₂ T4 Gb, IP67, 90–240 VAC, 15 W); 600B general purpose (10–26 VDC, 10 W); 90-day cal interval, air background ✓$$$datasheetpage
H2scanHY-OPTIMA 5031/5032/5033/5034 — HY-OPTIMA 5030 Gen-5 in-line process analyzer0–10% (5031) to 0–100% (5033/34); LDL 0.03–0.5%; T90 60–90 s; CO/H₂S tolerance model-dependent (5034: 20% CO/3% H₂S); RS-485 Modbus RTU 19200 baud, 4-20mA opt., IP68, 9–48 VDC, 10 W ✓$$$datasheetpage
H2scanHY-OPTIMA 700B / 2700 / 1700 — HY-OPTIMA process analyzersSolid-state Pd:Ni, non-consumable; 710B 0.1–10%, 720B 0.4–5%, 730B/740B 0.5–100% H₂; 2700 explosion-proof; <95% RH non-cond.; 1700 discontinued (ATEX/IS) ✓$$$datasheetpage
ServomexSERVOTOUGH H2scan — SERVOTOUGH H2scan hydrogen process analyzerPalladium-alloy (Pd/Ni) thin-film resistive H₂ sensing (H2scan technology base); solid-state, non-consumable; typically paired with SERVOTOUGH SpectraScan 2400 ✓$$$$datasheetpage
ServomexZirconia Gas Analyzer — Zirconia O₂ process/combustion analyzerY₂O₃-stabilized ZrO₂ cell at 600–800 °C with catalytic electrodes; O₂ (not H₂) for cement/power/pulp ✓$$$$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
AppliedSensor (ams-OSRAM)HLS-440 / HLS-440P / HLS-442 — HLS-44x Field-Effect hydrogen leak sensorHeated FET catalytic-gate + thermal-conductivity channel; HLS-440P 0–10% H₂, IP6K9, ATEX Zone 2, CAN; crash-tested on FCEV SUVs; HLS-442 0–4.4% H₂, ±3000 ppm accuracy, T90 <2 s, CAN 500 kbit/s, 75 mA typ., −40 to 85 °C, IP67, 10-yr life, SIL2/ATEX 100a ✓$$$datasheetpage
SenSiCiCSiC / iQSiC / EmiSiC — SiC-FET in-situ exhaust gas sensorsSiC ceramic-encapsulated sensor placed directly in hot exhaust; iQSiC CO probe: 225–325 °C op. (450 °C max non-destructive), T90 <10 s, ≥2 yr life, H₂ cross-sensitivity ~30% (i.e. H₂-responsive); in-situ placement removes sample-cooling lag (combustion/emissions/NH₃-slip) ✓$$$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
2Witech SolutionsHybridized High-Q Plasmonic H₂ Sensor — ARPA-E H2SENSE plasmonic H₂ sensorPlasmonic metasurface + H₂-permeable self-cleaning coating; target first mobile 20 ppb self-cleaning plasmonic sensor; no independent result published yet ✓unknowndatasheetpage
InsplorionM8 / S2 Flow / X1 — NPS battery/electrochemistry analysersSame NPS platform, fiber-optic sensor chips; up to 8 operando cell channels; retained after H₂-business divestment ✓$$$datasheetpage
InsplorionNPS-P2 — NPS-P2 nanoplasmonic hydrogen detectorPd-alloy LSPR; 0.4–4 vol% H₂; t90 <5 s; ±0.2 vol% or ±25% of reading; 24 VDC, TTL / 4–20 mA; IP64; 500 g; ATEX zone 1 in progress ✓$$$datasheetpage
Mann Teknik (MannTek)NPS-P2 (post-acquisition) — H₂ sensing integrated into refueling couplingsAcquiring NPS-P2 IP/product; 30-yr background in cryo/LH2 couplings (truck/ship/aviation); deal pending shareholder approval ✓$$$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
GLOphotonicsPowerLink (PMC) — PowerLink Photonic MicroCell (IC HC-PCF)Hermetically-sealed gas-fillable HC-PCF module; broadband UV–IR; <10 dB/km loss reported; OEM component, no public unit pricingunknowndatasheetpage
Intelligent Optical SystemsMulti-point fiber-optic H2 leak system — Fiber-optic H₂ leak-detection system (custom)Optrodes w/ temperature-sensitive/chemochromic indicators on telecom fiber; field-demoed 2001 (Boeing/Delta IV, NASA Stennis); program/contract-basedunknown—page
NKT PhotonicsHC-800(-B) / HC-1550(-02) — Hollow-core photonic-crystal fiberPhotonic-bandgap hollow-core fiber; low-loss windows (e.g. 1500–1650 nm for HC-1550-02); OEM fiber, no public unit pricing ✓unknowndatasheetpage
Precise Downhole SolutionsPureLight FOPG — PureLight Fiber-Optic Pressure GaugeSapphire/quartz fiber gauge for 'high temperature / hydrogen rich' wells; up to 30,000 psi; 10 samples/s (P/T, not H₂ concentration)$$$datasheetpage
Technica Optical ComponentsT910 — T910 Hydrogen Detection SensorCatalytic-combustion twin custom FBG transducer, single-mode fiber; response 'within seconds'; daisy-chainable; EMI/lightning-immune; self-T-compensated; SS package ✓$$$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
Element OneChemochromic paints / inks / decals — Visual Hydrogen Detection lineSame pigment chemistry as DetecTape in paint/ink/molded/film formats; threshold as low as 0.04% (1/100 LFL); reversible or non-reversible ✓$$datasheetpage
Element OneDetecTape H2 — DetecTape H₂ visual leak tapeChemochromic silicone tape; gray→black in minutes; −54 to +232 °C; 1"/2" × 15 ft rolls; gas-permeable; NREL-validated (2016); $129–185/roll ✓$$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
Endress+HauserProsonic Flow G300 / FLOWSIC610 — Ultrasonic flow with H₂ purity optionToF ultrasonic; custody-transfer H₂ up to 30% blends (FLOWSIC600-XT: MID-approved custody transfer for pure/blended H₂, DN50-DN400, fiscal accuracy class 1, 1000 kHz electronics); ≤±0.2–0.5% accuracy classes (FLOWSIC610 attribution per dossier) ✓$$$$datasheetpage
Endress+HauserRaman Rxn-30 — Raman Rxn-30 gas-phase probeGas-phase headspace/in-situ probe for Rxn5/Rxn4/Rxn2; 316/316L SS, PTFE, sapphire, fused silica; to 68.9 barg/1000 psig, −20 to 150 °C; ATEX/CSA/IECEx/UKCA/JPEx; validated for parahydrogen-conversion monitoring in H₂ liquefaction ✓$$$datasheetpage
Endress+HauserRaman Rxn2 — Raman Rxn2 benchtop/cart + WetHead immersion probe532/785/1000 nm; 100–4350 cm⁻¹ (≈535–692 nm scattered at 532 nm); deployed via 100 m fiber into a flooded borehole for dissolved-gas Raman (H₂ not yet) ✓$$$$datasheetpage
Endress+HauserRaman Rxn4 — Raman Rxn4 analyzer532/785/1000 nm (hybrid 785 nm option); 150–4350 cm⁻¹ (532 nm; ≈536–692 nm scattered) / 150–3425 cm⁻¹ (785 nm; ≈794–1074 nm) / 200–2400 cm⁻¹ (1000 nm; ≈1020–1316 nm); marketed for LNG/refining/energy gas-phase Raman incl. ammonia production ✓$$$$datasheetpage
Endress+HauserRaman Rxn5 (KRXN5C) — Raman Rxn5 process analyzer532 nm; 150–3425 cm⁻¹ (≈536–651 nm scattered), 5 cm⁻¹ res; up to 4 ch; <300 W; −20 to +50 °C; IP56; ATEX/CSA/IECEx; fiber probes to 500 ft, 70 bar/150 °C; derives Wobbe/heating value ✓$$$$datasheetpage
Endress+HauserRamanRXn1 — RamanRXn1 (HoloPlex)NIR 'Invictus' laser; HoloPlex grating single-shot full-spectrum; gas-phase probe accessory ✓$$$$datasheetpage
Fraunhofer IPMFilter-based H₂ Raman sensor — TransHyDE low-cost H₂ Raman sensor532 nm; bandpass-filtered ~4150 cm⁻¹ (≈683 nm scattered) H₂ Q-branch onto low-cost CMOS camera; portable form factor; low-cost design goal ✓$datasheetpage
IS-InstrumentsAura — Aura HC-MOF gas Raman analyzerHC-MOF Raman; sensitivity ~0.04% (~400 ppm); tested 0.5–2.0 barg; detects H₂/D₂/HD; H₂ pipeline-blending / emissions / fusion-fuel targets ✓$$$$datasheetpage
Metrohm2060 RISE — 2060 RISE Raman Intelligent SEnsor785 nm inline Raman spectrometer; RISE/RISE-HT/RISE-Ex/RISE-HT-Ex variants; real-time process/reaction monitoring, raw-material and impurity detection ✓$$$$datasheetpage
Metrohm2060 Raman Analyzer — 2060 process Raman analyzer785 nm; continuous inline; up to 5 sampling streams; integrated reference channel for calibration ✓$$$$datasheetpage
NETL (US DOE)Raman Gas Analyzer (RGA) — RGA compact rack-mount Raman prototype532 nm, 150 mW; reflective hollow waveguide >1000× signal boost; 1 s target; 0.1 vol% accuracy target; up to 1000 psi; TRL ~5–6unknown—page
Spectral SciencesRaman Hydrogen Sensor — Free-space laser Raman H₂ sensor (historical)Free-space Raman optimized for fast response; 0.0013 atm (~1300 ppm) LOD; 0.3 s response; 18 mW laser; R&D/government programunknown—page
tec5 (tec5USA)Raman Spectrometer for natural gas — tec5 natural-gas Raman spectrometer785 nm, 35–500 mW tunable; 1024×58 CCD; VPH gratings; 300–3100 cm⁻¹ (≈804–1038 nm scattered); Hellma Multipass / tecRaman probes ✓$$$datasheetpage
Tornado Spectral SystemsRaman analyzers (O&G / LNG) — Process Raman analyzersProprietary high-throughput Raman; explicitly measures homonuclear diatomics (H₂/N₂/O₂) inaccessible to IR; product names not confirmed$$$$datasheetpage
Xcalibur Smart MappingH-MAS — Hydrogen Mapping Airborne SpectrometerAirborne standoff Raman scattering of near-surface atmosphere for remote H₂ mapping; no verified LOD published; survey-service model ✓unknowndatasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
Aeris TechnologiesMIRA Pico — MIRA Pico mid-IR TDLAS analyzerDirect-absorption TDLAS; CH₄/C₂H₆/CO₂/CO/N₂O/CH₂O/OCS/C₂H₂; <3 kg, 18 W, 60 cc cell, 1–5 Hz; 'sub-ppb precision' (vendor claim) ✓$$$$datasheetpage
AxetrisLGD Compact-A — LGD Compact-A TDLS moduleTDLS; CH₄/CO₂/C₂H₆/NH₃/H₂O/C₂H₂ variants; CH₄ LDL ≤0.4 ppm (≤0.15 @10 s); T90 ≤1.8 s; −10 to 55 °C; 3.7–30 VDC ✓$$$datasheetpage
Carl ZeissZGL 2505 — ZGL 2505 gas interferometer (historical)1957-era portable methane/CO₂ interferometer (Teralba Colliery); optical-interferometric gas measurement; no longer manufacturedunknown—page
EmersonRosemount ultrasonic flow — Ultrasonic flow meter (H₂ purity option)ToF ultrasonic flow; certified for custody-transfer H₂ up to 30% blends; ≤±0.2–0.5% accuracy classes$$$$datasheetpage
EmersonUVS-H2 / UV/IRS-H2 — Net Safety / Rosemount UV/IR hydrogen flame detectorUV 185–260 nm (+IR); 120° FOV; 55 ft / 1.8 s response; −50…+75 °C; CSA/ANSI-UL/ATEX ✓$$$datasheetpage
FLIRGF343 — GF343 OGI thermal camera (discontinued)InSb 3–5 µm cooled, filtered ~4.3 µm; used with 3–4% CO₂ tracer gas to visualize H₂ leaks in >95%-purity generator cooling ✓$$$$datasheetpage
Gasmet TechnologiesDX4000 — DX4000 portable FTIRUp to 50 gases (CO₂/CH₄/CO/H₂S/NH₃/VOCs); 8/4 cm⁻¹ res, 900–4200 cm⁻¹ (2.4–11.1 µm); 5 m heated (180 °C) cell; T90 <120 s; 150 W avg; 13.9 kg ✓$$$$datasheetpage
LI-COR BiosciencesLI-7810 — LI-7810 OF-CEAS analyzerCH₄ 0.25–0.6 ppb; CO₂ 1.5–3.5 ppm; H₂O; −25 to 45 °C; 0–85% RH; <1 ppb/24 h drift ✓$$$$datasheetpage
LI-COR BiosciencesLI-7815 — LI-7815 OF-CEAS CO₂ analyzerOF-CEAS; CO₂ 0–10,000 ppm, 0.04 ppm precision @400 ppm/5s, <0.2 ppm/24h drift; H₂O 100–60,000 ppm; −25 to 45 °C; 10.5 kg incl. batteries; 8 h battery life ✓$$$$datasheetpage
Malvern PanalyticalHandheld LIBS (SciAps Z-903 distribution) — Handheld LIBS elemental analyzerDistributes SciAps Z-903 (H-capable, 190–950 nm); general elemental/alloy ID; ~$40k–55k reported ✓$$$$datasheetpage
MinEx CRCDownhole LIBS logging tool — Pre-commercial downhole LIBS logger75 mm OD, ~1.7 m, <5 kg, wireline; NQ-borehole compatible; 60–300 analyses/m at 2–10 m/min; field trials onlyunknown—page
mirSenseMIRCHIP X — MIRCHIP X QCL OEM multigas moduleQCL-based compact OEM multigas analyser module (customer-specified gases); mass-scale-production chip form factor, easily integrable into customer systems ✓$$$datasheetpage
mirSensemultiSense — multiSense QCL photoacoustic analyzerQCL + photoacoustic cell; hydrocarbons incl. CH₄/NH₃/NO/NO₂/SF₆/CF₄; matchbox-sized; sub-ppm LOD (vendor claim)$$$$—page
PicarroG2201-i — G2201-i CRDS isotopic analyzerWS-CRDS; CO₂ 200 ppb+0.05% (1σ,30 s); CH₄ 1 ppm+0.25%; δ¹³C ✓$$$$datasheetpage
PicarroG2401 — G2401 CRDS analyzerCO₂/CO/CH₄/H₂O, multi-species simultaneous, ppb-class ✓$$$$datasheetpage
PicarroGasScouter G4302 — G4302 portable CRDSPortable/battery; CH₄ 3–30 ppb; C₂H₆ 1–10 ppb; 25 lb, 35 W, 6 h battery ✓$$$$datasheetpage
SciApsZ-901 — Z-901 handheld LIBSLower-cost; explicitly CANNOT measure H/Li/Na/C/N/O/Cl/Br/F/Ce/Rb/S per vendor spec (procurement-relevant vs Z-903) ✓$$$$datasheetpage
SciApsZ-903 — Z-903 handheld LIBS190–950 nm triple-spectrometer; measures H via extended range; full periodic table H→U; PULSAR laser 5–6 mJ, up to 50 Hz; ~4 lb; ~$40k–55k class ✓$$$$datasheetpage
Thermo Fisher ScientificDelta V + TC/EA — Delta-series IRMS for δD-H₂H/D, ¹³C, ¹⁵N, ¹⁸O, ³⁴S ratios; δD precision ~±2‰ (2σ) via TC/EA; high-capex lab; quote-only$$$$datasheetpage
Thermo Fisher ScientificNiton Apollo — Niton Apollo handheld LIBSHandheld LIBS, carbon-equivalency/alloy focus; Class 3b laser; 6.4 lb (2.9 kg); IP54; two hot-swap batteries, 3–5 h life; results in ~10 s ✓$$$$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
Agilent Technologies990 Micro GC / 990 Mobile Micro GC — 990 Micro GC (µTCD)MEMS µTCD; 1.5–3 min/channel; MolSieve 5A + PoraPLOT U; field case ~16 h autonomy, 12 VDC/180 W; mixed He/H₂ carrier H₂ method ✓$$$$datasheetpage
AMETEK Process Instrumentsta3000R / ta5000R — Reduction Gas Analyzer (RGA)HgO reduction / UV photometric; factory LDL 25 ppb H₂ (bulk) / 50 ppb (dissolved); 10 ppb CO; accuracy ±10 ppb or ±10%; 35 lb ✓$$$$datasheetpage
ChromatotecChroma DID (Auto-GC 866) — Chroma DID discharge-ionization GCPDHID-class DID; 50–100 ppb LOD (<50 ppb special); 10–15 min cycle; He carrier, 3 bar, ≤50 mL/min$$$$datasheetpage
ChromatotecChromaTCD (Auto-GC 866) — ChromaTCD continuous GC-TCDContinuous permanent-gas + light-HC monitor; H₂ from ppm to %; integrated H₂ generator supplies TCD carrier gas ✓$$$$datasheetpage
INFICONHAPSITE — HAPSITE handheld GC/MSBattery-portable GC/MS with library matching; VOC/CWA focus; no H₂ capability found$$$$datasheetpage
INFICONMicro GC Fusion — Micro GC Fusion (MEMS µTCD)Vendor 1 ppm H₂ LOD, '≥10× more sensitive than traditional TCD'; dual Ar/He carrier for pipeline H₂; ~1–4 cc/min carrier; quote-only ✓$$$$datasheetpage
Peak LaboratoriesPeak Performer 1 RCP — Reducing Compound PhotometerHgO reduction / UV photometric; LOD 800 ppt H₂ / 300 ppt CO in N₂/Ar/He/O₂; 1000:1 linear; <2 min run ✓$$$datasheetpage
SRI Instruments310 Soil-Gas GC — 310 / Natural Gas Analyzer GCTCD (+FID option); TCD-only LOD ~200–300 ppm; water-vapor tolerant; field/battery-portable; ~$5,000–20,000+ (not re-verified) ✓$$$datasheetpage
SRI Instruments8610C (8610D / 310) — Field-portable gas chromatographUp to 6 of 16 detectors (TCD/FID/RGD/HID/ECD/PID/FPD); oven ambient–400 °C; TCD LOD ~100 ppm; mainframe $8,944–12,235, configured $16k–32.6k (2023) ✓$$$datasheetpage
SRI InstrumentsHID — Helium Ionization Detector (SRI design)Pulsed/DC He ionization; universal permanent-gas, non-radioactive; bare $4,738, chassis $7,116 ✓$$$datasheetpage
SRI InstrumentsRGD — Reduction Gas Detector (add-on)HgO reduction / UV photometric; ~3 ppb H₂ reported (500 ppb on unoptimized bench); 250 °C reactor; bare $5,810, chassis $8,188 ✓$$$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
908 DevicesMX908 / M908 — Handheld high-pressure mass spectrometerHigh-pressure MS (>1 Torr), ion-trap array, ambient ionization; ~2 kg; explosives/narcotics/CWA focus; no H₂ capability found$$$$datasheetpage
GasometrixminiRUEDI — miniRUEDI field-portable MIMSBase He/Ne/Ar/Kr/N₂/O₂/CO₂ (extended methods for CH₄/H₂S/H₂); ΔM ≤0.5 amu; 50 W; 32 kg; battery/solar-capable; quote-only ✓$$$$datasheetpage
Hiden AnalyticalHPR-40 DSA / DEMS — Membrane-inlet MS (MIMS)1–200/300 amu; 100%–60 ppt sensitivity; up to 650 meas/s; dual Faraday/Channeltron; PDMS membrane inlets; ~33 kg; quote-only$$$$datasheetpage
Hiden AnalyticalQGA / QGA 2.0 — Transportable quadrupole gas analyzerHAL 201 RC quadrupole; 1–200 amu; 100 ppb–100% dynamic range; up to 1000 meas/s; H₂-compatible vacuum (QGA 2.0); quote-only$$$$datasheetpage
Hiden AnalyticalpQA — Portable Quadrupole Analyser (MIMS, field-portable)Field-portable MIMS in Pelican case; 200 amu (300 amu option); sub-ppb dissolved-gas sensitivity; 12 V/battery/solar or 220 V; interchangeable membrane-inlet probes (direct, flow-through, circular cell) for groundwater/sediment dissolved-H₂ studies; quote-only ✓$$$$datasheetpage
Pfeiffer VacuumASM 340 / ASM 306 S — ASM-series helium/hydrogen sniffer leak detectorDry vacuum-pump QMS leak detector for He or H₂ tracer gas; MDL vacuum mode 1×10⁻¹² mbar·l/s, sniffer mode 1×10⁻⁹ mbar·l/s (ASM 340); tabletop, touchscreen; not a stand-alone ambient-H₂ concentration monitor$$$$datasheetpage
Pfeiffer VacuumOmniStar / ThermoStar GSD 320 — GSD 320 process/TGA-offgas QMS1–100/200/300 amu; DL <1 ppm (C-SEM) / <40 ppm (Faraday); heated capillary inlet 200–350 °C; superseded in current catalog by GSD 350 (OmniStar/ThermoStar); quote-only$$$$datasheetpage
SLB (Schlumberger)DQ1000 — DQ1000 wellsite mass spectrometerQuadrupole MS; H₂ ~50 ppm–15/20 vol% once QC'd; ~90 s cycle; C1–C10 + inorganics; 61 lb portable ✓$$$$datasheetpage
SLB (Schlumberger)FlairFlex — FlairFlex real-time fluid logging & analysisGC-MS; dual inbound/outbound extraction at constant thermodynamic condition; lists CO₂/He/hydrogen; C1–C6 quantified, C7–C8 qualified ✓$$$$datasheetpage
SLB (Schlumberger)MDT Forte / MDT Forte-HT — Wireline formation tester + InSitu Fluid Analyzer / LFAForte-HT to ~410 °F (~210 °C), ~31,500 psi; optical H₂S at ~1590 nm; H₂ not detectable ✓$$$$datasheetpage
Stanford Research SystemsQCM200 — QCM200 quartz-crystal microbalanceGeneral-purpose lab QCM (frequency counter + resistance meter); ~$2,795 base; usable Pd-QCM research platform, not an H₂ product ✓$$$datasheetpage
Stanford Research SystemsRGA100 / RGA200 / RGA300 — Residual gas analyzer (QMS)1–100/200/300 amu; ΔM₁₀%<0.5 amu; 2×10⁻⁴ A/Torr (FC); MDPP 5×10⁻¹¹ Torr (FC) / 5×10⁻¹⁴ (CDEM); ~US$4,950 base (historical, unverified) ✓$$$datasheetpage
Stanford Research SystemsUGA100 / UGA200 / UGA300 — Universal Gas Analyzer (atmospheric-inlet RGA)RGA (1–100/200/300 amu) + two-stage capillary pressure-reducing inlet for direct atmospheric-pressure sampling; 6 decades dynamic range; MDPP to 5×10⁻¹⁴ Torr (CDEM); used for trace gas/fuel-cell/glovebox H₂ studies ✓$$$datasheetpage
VendorProduct / SKUKey specsPriceDatasheetModality
Excellence LoggingSAFE fluid logging — SAFE modular fluid-logging platformModular upgradeable gas chain (standard→fluid-logging without full swap); states natural-hydrogen exploration know-how / H₂ detection experience ✓$$$$datasheetpage
GeologG5 (DualFID) — G5 DualFID light-hydrocarbon gas chromatographDual-FID wellsite GC for C1–C5 light-hydrocarbon speciation; constant-volume mud trap + mud heating + contaminant removal; H₂ channel not confirmed$$$$datasheetpage
GeologG8 (DualFidStar) — G8 DualFidStar extended-range gas chromatographExtended C1–C8+ wellsite GC platform (successor/companion to G5); H₂ channel not confirmed$$$$datasheetpage
GeologMPD formation-gas system — Modular Platform Drilling gas extractionCVT-class calibrated extraction by mud type; GC-based; states real-time surface alkene and H₂ detection informs drilling; H₂-specific not confirmed$$$$datasheetpage
HalliburtonBaseline 8900 GC — C1–C8 gas chromatograph (GasFact component)Wellsite GC used within GasFact service for C1–C8 hydrocarbon speciation; H₂ channel not confirmed in materials reviewed$$$$datasheetpage
HalliburtonGasFACTS — GasFact advanced gas analysis serviceConstant volume+temperature extraction (CVE Thermal Plus); Baseline 8900 GC / 9000 THA; IsoLogger GC-C-IRMS; H₂-specific capability not confirmed in materials reviewed ✓$$$$datasheetpage
HalliburtonIsoLogger — IsoLogger GC-C-IRMS isotopic gas analysis (GasFact component)Wellsite GC-combustion-IRMS for compound-specific carbon-isotope logging; part of GasFact isotopic gas analysis offering; H₂/δD capability not confirmed$$$$datasheetpage
SEMM LoggingWellsite mud-gas logging — Wellsite mud-gas logging serviceStandard mud-gas extraction + gas chromatograph; confirmed 98% H₂ / 1% N₂ / 1% CH₄ at Bourakebougou discovery well$$$$—page
VendorProduct / SKUKey specsPriceDatasheetModality
DistranUltra / Ultra Pro / Ultra Pro Max / Ultra Pro X — Ultrasound-array acoustic gas-leak imager124-element array; Ultra Pro ~0.3 L/h @30 cm (4-bar), 0.3–100 m; Ultra Pro Max ~0.15 L/h; ATEX variants ✓$$$$—page
Flukeii910 / ii900 — Sonic Industrial Imager (acoustic leak camera)2–100 kHz; up to ~120 m range; 7" touchscreen; LeakQ/PDQ/MecQ; ii910 ≈ $28,550 new ✓$$$$—page
SENSeORTSA F151/F191 / TA31 — Passive wireless SAW temperature sensorsBattery-less wireless SAW telemetry, thermowell-mount; fielded by RTE for HV equipment; temperature, not gas (proves the SAW platform)$$$—page
Transense TechnologiesGlobal SAW Tag — SAW torque & temperature sensing systemSAW torque/temperature with custom RF ASIC interrogator ('Global SAW Tag'); rotating-machinery/condition monitoring; not an H₂ product$$$—page
VendorProduct / SKUKey specsPriceDatasheetModality
Axiom SensingEVA — EVA (Exploration Vapour Analysis) passive H₂ loggerPassive (non-pumped) continuous soil-gas H₂ + CO₂/T/P logger; diurnal cH₂ correlated with barometric pressure ✓$$$datasheetpage
Axiom SensingWHALI — WHALI pumped autonomous H₂ loggerEC H₂ 0–2000 ppm, ±10 ppm; ~300 mL/min pump; solar-capable; weeks-long autonomy; also measures CO₂/H₂S/CH₄/T/P with water management for high-groundwater sites ✓$$$datasheetpage
CrowconPortable multi-gas detectors — Multi-gas detectors (cross-sensitivity reference)Publishes H₂-driven CO false-reading tables (e.g. 18/36/54 ppm at 10/20/30 °C) ✓$$$datasheetpage
ENGIEPARHyS — PARHyS telemetered soil-gas H₂ stationEC + T/RH compensation, LoRa telemetry; sensitivity ≤2 ppm; T90 <30 s; ≤500 mL/min pump; ~1-yr battery; ~100 units in Brazil$$$—page
EnvironicsSeries 4040 — Dynamic dilution calibrator±1% of setpoint, ±0.05% repeatability; MFCs NIST-traceable w/ 11-point linearization; electropolished SS path ✓$$$$datasheetpage
Geo Numeric / ISTerreMONHyTOR — MONHyTOR buried H₂ soil probeEC, non-pumping; 0–1000 ppm; 0.1 ppm resolution; ±5% FS; 1 Hz capable; months autonomy; buried ~950 mm; internally RH-regulated ✓$$$datasheetpage
Hermann SewerinVARIOTEC 460 Tracergas — VARIOTEC 460 Tracergas leak detectorTCD 0–100 vol% + MOX ppm channel; claimed 0.1 ppm resolution (semiconductor); dual-range 0–10,000 ppmv fine / 0.1–100 vol% coarse; ≥8 hr on 4×AA ✓$$$datasheetpage
Industrial ScientificVentis MX4 / Ventis Pro / Tango / MX6 (iBrid) — Portable multi-gas platforms (CO/H₂-low option)H₂ to ~2000 ppm on CO/H₂-low config; iBrid MX6 ~1–10 ppm precision; publishes cross-interference tables ✓$$$datasheetpage
LeutertPDSshort / PDSeven / Geothermal Fluid Sampler — Positive-displacement fluid samplersGeothermal sampler −20…250 °C, titanium, gas-tight, multi-sample; no published H₂-specific tightness spec (ask directly) ✓$$$datasheetpage
McPhersonModel 234 / 302 — VUV monochromator/spectrometer200 mm focal length, f/4.5, 1200 g/mm aberration-corrected grating; MCP/CCD detector options ✓$$$datasheetpage
McPhersonModel 632 / 634 — Deuterium VUV lamp115 nm–visible; MgF₂ window; 30 W; 2000 h life; lab light-source pricing (contact vendor) ✓$$$datasheetpage
ProservPDS / single-phase samplers — Downhole bottom-hole sampling toolsMK II PDS Downhole Sampler (600cc) + PDS-SPS single-phase inert-coated variants; standard & 'exotic' materials, harsh-environment & non-reactive-coating options; wireline slickline/electricline deployment, mechanical clock or surface electric firing ✓$$$datasheetpage
QED Environmental Systems / GeotechBIOGAS 5000 — BIOGAS 5000 multi-gas analyzerOptional EC H₂ cell 0–1000 ppm; primary CH₄/CO₂/O₂ channels ✓$$$datasheetpage
QED Environmental Systems / GeotechGA2000 — GA2000 landfill gas analyzerEC multi-gas (H₂/O₂/CO₂/CH₄ ± CO/H₂S); industry-standard soil-gas survey instrument; discontinued/superseded by GA5000 (~25% smaller/lighter), no current official datasheet found$$$—page
QED Environmental Systems / GeotechGA5000 — GA5000 portable multi-gas analyzerEC H₂ 0–1000 ppmv (±2.5% FS field-validated); IR CH₄/CO₂ ±0.5–1.5%; O₂; K>1000 selectivity; pump 550 mL/min; IP65; ATEX/IECEx/CSA/MCERTS; ~$5,000–8,000 ✓$$$datasheetpage
West SystemsPortable Fluxmeter — Soil diffuse-flux accumulation chamberMeasures CO₂/CH₄/H₂S/VOC; no H₂ channel identified in sources reviewed$$$—page
VendorProduct / SKUKey specsPriceDatasheetModality
Air LiquideALPHAGAZ / specialty mixtures — Certified calibration gas mixturesISO/IEC 17025 + ISO 17034 certified; % to ppm to ppb accuracy classes; up to 40-component mixtures ✓$$—page
AirgasEPA Traceability Protocol gases — Protocol-certified standards±2% of tag value (95% CI) per EPA Traceability Protocol (EPA/NIST/industry) ✓$$—page
AMS, Inc.Gas Vapor Probe (Retract-A-Tip, 210.01) — GVP driven soil-gas probe300/400-series SST; 3/16" ID tubing; slide-hammer or rotary-hammer driven; ~$300/unit (probe only) ✓$$—page
CoherentLEAP UV series — LEAP UV ArF excimer laser193 nm; mJ-class pulses; kHz rep rates; ~$195,000 for a compact 193 nm research system (vendor-listed) ✓$$$$—page
CrystranMgF₂ / LiF windows — VUV-grade MgF₂ and LiF windowsLiF transmission from 105 nm (~40% at 121 nm, solarizes); MgF₂ to ~115–120 nm; $100s–$1,000s per window$$—page
Edmund OpticsLiF / VUV-grade windows — VUV-grade LiF windows (ISP Optics)Transmission from ~105 nm; ~40% at 121 nm; solarizes with VUV dose; $100s–$1,000s per window$$—page
Entech InstrumentsSumma canisters — Summa passivated whole-air canisterGC-MS gold-standard whole-air canister; documented H₂-generation risk from canister-wall chemistry$$—page
FemtoFiberTecfs-inscribed Type-II FBGs — Femtosecond-inscribed Bragg gratingsfs-laser Type-II FBGs, ~50% reflectivity, 1550 nm, SMF-28; component for custom Pd-coated FBG H₂ sensors$$—page
GigaphotonGT40A — GT40A ArF excimer laser193 nm, 45 W, lithography-class; lithography-grade systems substantially higher-priced than research units$$$$—page
HamamatsuL1835 / L7293 / S2D2 — Deuterium VUV lamps115–400 nm; MgF₂ window; photoionization-source variants; lab component pricing ✓$$—page
HamamatsuR821 — R821 solar-blind PMT (Cs-Te)Spectral response ~160–320 nm; component pricing (price on request) ✓$$—page
HamamatsuUVTron R2868 — UVTron R-series solar-blind UV flame tube185–260 nm gas-discharge UV tube; OEM component; detects lighter flame >5 m, H₂ burner flame ~10 m in vendor app testing ✓$—page
KIN-TEK AnalyticalTrace Source permeation tubes — Permeation-tube trace generationNIST-traceable cert per tube; 500+ compound catalog; ~0.1–200 ppm at ~±1% for well-characterized compounds ✓$$—page
LabcoExetainer (12 mL) — Exetainer 12 mL butyl-septum vialGas sample vial; not H₂/CO-stable untreated; stable >60 days when modified per method$—page
LindeSpecialty Gas Mixtures / NTRM — NIST-Traceable Reference Material mixturesNTRM (EPA-recognized equivalent to NIST SRM); custom ISO 17025 mixtures; vendor ±1% NIST-traceable claim ✓$$—page
nanoplusDFB laser diodes (2200–2600 nm family) — DFB laser diode sourcesCustom wavelength to 0.1 nm across 760 nm–14 µm; enabling source for CH₄/CO/N₂O/HF and the 2121.8 nm H₂ quadrupole-line sensor ✓$$$—page
National K WorksVacuum-flask tool housings — Dewar-flask downhole electronics housingsPassive 'buy hours, not days' thermal protection for above-rated-temperature downhole electronics$$$—page
NISTSRM / NTRM gas standards — Standard Reference Material gas mixturesNIST-issued SRMs certified via Certificate of Analysis; underlies EPA Protocol Gas traceability chain ✓unknown—page
SKCTedlar bags — Tedlar (PVF) gas sampling bagsReported good stability for H₂, CO, CH₄, CO₂, SF₆; consumable, low cost$—page
SST SensingZirconia Oxygen Sensor System — ZrO₂ closed-loop O₂ sensorZrO₂ cell, no reference gas needed; −100…+250 °C housing; 0.1–100% O₂; T90 <4 s; 0.01% O₂ res; 4–20 mA/0–10 V/RS485; up to 10-yr life (O₂, not H₂) ✓$$$—page
ThorlabsHC10L/M / HC30L/M — Herriott multipass gas cells10.4 m / 31.2 m path variants; protected-gold mirrors; individually vacuum/leak tested; component (~$1k–5k/cell, not re-verified)$$$—page
ThorlabsMgF₂ windows/viewports — VUV/UV MgF₂ windowsTransmission to ~115–120 nm; >50% at 120 nm; UHV/CF/KF flange options ($100s–$1,000s)$$—page
VICI (Valco Instruments)D-2 / D-4 PDD — Pulsed Discharge Detector (PDHID/PDD)Universal He-photoionization mode, low-ppb MDQ for fixed gases; also configurable as selective electron-capture detector ✓$$$datasheetpage
VICI (Valco Instruments)D-3-I-HP — Pulsed Discharge Detector, high-purity hydrogen configurationPDHID mode marketed specifically for trace-impurity analysis in high-purity H₂ background; discharge gas separate from carrier so bulk H₂ matrix peak bypasses discharge region for fast recovery; low-ppb MDQ ✓$$$datasheetpage
VendorCategoriesHQProductsStatus
2Witech SolutionsplasmonicUnited States1research-stage
908 DevicesmsUnited States1active
ABBthermal-conductivity, optical, instrumentsSwitzerland4acquired
Aeris TechnologiesopticalUnited States1active
Agilent TechnologiesgcUnited States1active
Air LiquidecomponentsFrance1active
AirgascomponentsUnited States1acquired
AlphasenseelectrochemicalUnited Kingdom2acquired
AMETEK Process InstrumentsgcUnited States1acquired
AMS, Inc.componentsUnited States1active
AppliedSensor (ams-OSRAM)work-functionGermany1acquired
AxetrisopticalSwitzerland1active
Axiom SensinginstrumentsAustralia2active
Baker Hughes / Panametricsthermal-conductivityUnited States1active
Blackline SafetypellistorCanada1active
Boschmox, work-functionGermany2active
Carl ZeissopticalGermany1discontinued
ChromatotecgcFrance2active
CoherentcomponentsUnited States1active
CrowconinstrumentsUnited Kingdom1active
CrystrancomponentsUnited Kingdom1active
DD-ScientificelectrochemicalUnited Kingdom5active
DistranacousticSwitzerland1active
Drägerelectrochemical, pellistor, instrumentsGermany4active
E/One (Environment One)thermal-conductivityUnited States1active
Eaton / MTL (Crouse-Hinds)thermal-conductivityUnited Kingdom1active
EC SenseelectrochemicalUnited States2active
Edmund OpticscomponentsUnited States1active
Element OnechemochromicUnited States2active
Emersonoptical, instrumentsUnited States2active
Endress+Hauserraman, instrumentsSwitzerland6acquired
ENGIEinstrumentsFrance1research-stage
Entech InstrumentscomponentsUnited States1active
EnvironicsinstrumentsUnited States1active
Excellence Loggingmud-gas-loggingFrance/UAE1active
FemtoFiberTeccomponentsGermany1active
Figaro Engineeringmox, pellistorJapan5active
FLIRopticalUnited States1discontinued
FlukeacousticUnited States1active
Fraunhofer IPMramanGermany1research-stage
Gasmet TechnologiesopticalFinland1active
GasometrixmsSwitzerland1active
Geo Numeric / ISTerreinstrumentsFrance1research-stage
Geologmud-gas-loggingItaly3active
GigaphotoncomponentsJapan1active
GLOphotonicsfiber-opticFrance1active
H2scanpd-resistiveUnited States6active
Halliburtonmud-gas-loggingUnited States3active
HamamatsucomponentsJapan3active
Hermann SewerininstrumentsGermany1active
Hiden AnalyticalmsUnited Kingdom3active
Honeywellelectrochemical, pellistor, thermal-conductivityUnited States3acquired
Industrial ScientificinstrumentsUnited States1active
INFICONgc, msLiechtenstein2active
Infineonthermal-conductivityGermany1active
InsplorionplasmonicSweden2active
Intelligent Optical Systemsfiber-opticUnited States1active
IS-InstrumentsramanUnited Kingdom1active
KIN-TEK AnalyticalcomponentsUnited States1active
LabcocomponentsUnited Kingdom1active
LeutertinstrumentsGermany1active
LI-COR BiosciencesopticalUnited States2active
LindecomponentsIreland/Germany1acquired
Malvern PanalyticalopticalUnited Kingdom1active
Mann Teknik (MannTek)plasmonicSweden1active
McPhersoninstrumentsUnited States2active
MembraporelectrochemicalSwitzerland8active
MetrohmramanSwitzerland2acquired
MinEx CRCopticalAustralia1research-stage
mirSenseopticalFrance2active
MSA Safetypellistor, optical, acousticUnited States4active
nanopluscomponentsGermany1active
National K WorkscomponentsUnited States1active
NETL (US DOE)ramanUnited States1research-stage
NevadaNanothermal-conductivityUnited States2active
New Cosmos ElectricpellistorJapan2active
Nissha FISmox, pellistorJapan3active
NISTcomponentsUnited States1active
NKT Photonicsfiber-opticDenmark1active
Peak LaboratoriesgcUnited States1active
Pfeiffer VacuummsGermany2active
PicarroopticalUnited States3active
Posifa Technologiesthermal-conductivityUnited States3active
Precise Downhole Solutionsfiber-opticUnited States1active
ProservinstrumentsUnited Kingdom1active
QED Environmental Systems / GeotechinstrumentsUnited States3active
Renesas ElectronicsmoxJapan2active
SciApsopticalUnited States2active
SemeaTechelectrochemicalUnited States3active
SEMM Loggingmud-gas-loggingFrance1active
SENSeORacousticFrance1active
SenSiCwork-functionSweden1active
Sensirionmox, thermal-conductivitySwitzerland2active
Servomexpd-resistive, instrumentsUnited Kingdom2active
SGX Sensortechmox, pellistor, thermal-conductivity, electrochemicalUnited Kingdom9acquired
SKCcomponentsUnited States1active
SLB (Schlumberger)ms, mud-gas-logging, instrumentsUnited States3acquired
Spectral SciencesramanUnited States1research-stage
SRI InstrumentsgcUnited States4active
SST SensingcomponentsUnited Kingdom1active
Stanford Research Systemsms, instrumentsUnited States3active
tec5 (tec5USA)ramanGermany1active
Technica Optical Componentsfiber-opticUnited States1active
Thermo Fisher Scientificoptical, msUnited States2active
ThorlabscomponentsUnited States2active
Tornado Spectral SystemsramanCanada1active
Transense TechnologiesacousticUnited Kingdom1active
VICI (Valco Instruments)componentsUnited States2active
West SystemsinstrumentsItaly1active
Winsen Electronicselectrochemical, mox, pellistorChina6active
Xcalibur Smart MappingramanAustralia1research-stage
Xensor Integrationthermal-conductivityNetherlands1active